LP-2 Leep surgery system with built-out smoke vaccumlator
Leep surgery system
It is intended to be used for various lesion ( cutting, coagolation, erosion, LEEP, with all kinds of Laparoscopic surgery and gynecology surgery).
The specifacation of main engine
Specifications of LP-2
1. Classification: Class I Type CF
2. Main Frequency: 625kHz±5% Modulate Frequency: 25kHz±5%
3. Working Mode: Intermittent and continuous working, 10s/30s
4. Output power and peak voltage:
Surgical Modes | LP-2D | LP-2E | LP-2F | LP-2G |
Pure cutting | 350W(500Ω) | 350W(500Ω) | 350W(500Ω) | 350W(500Ω) |
Blend 1 | 250W(500Ω) | 350W(500Ω) | 250W(500Ω) | 250W(500Ω) |
Blend 2 | 200W(500Ω) | 350W(500Ω) | 200W(500Ω) | 200W(500Ω) |
Blend 3 | ——— | ——— | 200W(500Ω) | 200W(500Ω) |
Monopolar Contact Coagulation | 200W(500Ω) | 350W(500Ω) | 200W(500Ω) | 200W(500Ω) |
Monopolar Standard Coagulation | ——— | ——— | 200W(500Ω) | 200W(500Ω) |
Monopolar Spray Coagulation | ——— | ——— | 100W(500Ω) | 100W(500Ω) |
Bipolar Standard Coagulation | 70W(150Ω) | ——— | 70W(150Ω) | |
Bipolar Accurate Coagulation | ——— | ——— | 70W(150Ω) |
5. Automatic Storage: The working mode and output power set during operation can be stored in the unit for 100 years.
6. High Frequency Leakage Current
The neutral electrode is isolated from the earth during the high frequency operation, the High Frequency Leakage Current <150mA.
7. Output Setting and Indicating: The output is set by key pressing in different area according to different working mode, it is displayed digitally.
8. Output Indicating
Visual Indicator: Monopolar Cutting - Yellow / Coag - Blue / Bipo - Blue Audio Indicator: When the power is output, there is an audio indicator, the volume can be adjusted.
9. Error Indicating
Visual Indicator: The red indicator indicating the error and danger detected by self-detecting or monitoring (ALARM);
Audio Indicator: When alarming, there is an pulse audio indicating, this volume cannot be adjusted.
10. Main Supply: AC220V±10% 50Hz±2%
11. Operation Condition:
Environment Temperature: +5°C~+40°C
Relative Humidity: ≤85%
12. Transport and Storage Condition:
Environment Temperature: -40°C~+50°C
Relative Humidity: ≤90%
Specifacation of Smoke Vacuum
Max Flow Volume: 100 L/ min
Ventilate Strength: 10-100 ( air flow: 10 L/ min - 100 L/ min
Working noise: < 60dB
Control Method: Manual/ Foot/ Auto
Down delay time: 0-60s
Particle Remove Rate: 99.999% @ 0.1um
Bad smell removal rate: 97% @ 1 year
Warranty period:-
2 (two) years full including, repairing and servicing free of cost for all items from the date of installation. The warrantee of main unit of the system is one year. The maintenance of high frequency electrosurgical is based on its rule. Our company will be responsible for maintenance if the error is not caused by man-made reasons. Just the cost will be charged if the unit beyond the warrantee. Accessories are out of maintenance.
LP-2 Leep surgery system with built-out smoke vaccumlator