- Contact Person : Mr. Wan Bo
- Company Name : Anhui Yingte Electronic Company Ltd.
- Tel : 86-552-4086472,13909657386
- Fax : 86-552-4075119
- Address : Anhui,Bengbu,Bengbu High/New Tech Industrial Development Zone
- Country/Region : China
LP-1 leep instruments
Leep surgical instrument ----it is intended to be used for various lesion ( cutting, coagolation, erosion, LEEP, with all kinds of Laparoscopic surgery and gynecology surgery.
the specifacation of main engine
Specifications of LP-1D
1. Classification: Class I Type CF
2. Main Frequency: 625kHz±5% Modulate Frequency: 25kHz±5%
3. Working Mode: Intermittent and continuous working, 10s/30s
4. Output power and peak voltage:
Spec. Mode | Output Power | |
Power Range | Resistance | |
Monopolar Pure cutting | 5~350W | 500Ω |
Monopolar Blend 1 | 5~250W | 500Ω |
Monopolar Blend 2 | 5~200W | 500Ω |
Monopolar Contact Coagulation | 5~200W | 500Ω |
Bipolar Standard Coagulation | 2~70W | 150Ω |
14. Net Weight: 5.5 kg
Specifications of LP-1E
1. Classification: Class I Type CF
2. Main Frequency: 625kHz±5% Modulate Frequency: 25kHz±5%
3. Working Mode: Intermittent and continuous working, 10s/30s
4. Output power and peak voltage:
Spec. Mode | Output Power | |
Power Range | Resistance | |
Monopolar Pure cutting | 5~350W | 500Ω |
Monopolar Blend 1 | 5~250W | 500Ω |
Monopolar Blend 2 | 5~200W | 500Ω |
Monopolar Contact Coagulation | 5~200W | 500Ω |
5. Automatic Storage: The working mode and output power set during operation can be stored in the unit for 100 years.
6. High Frequency Leakage Current
The neutral electrode is isolated from the earth during the high frequency operation, the High Frequency Leakage Current <150mA.
7. Output Channels: Monopolar: 1 channel.
8. Output Setting and Indicating: The output is set by key pressing in different area according to different working mode, it is displayed digitally.
9. Output Indicating
Visual Indicator: Monopolar Cutting - Yellow / Coag - Blue / Bipo - Blue Audio Indicator: When the power is output, there is an audio indicator, the volume can be adjusted.
10. Error Indicating
Visual Indicator: The red indicator indicating the error and danger detected by self-detecting or monitoring (ALARM);
Audio Indicator: When alarming, there is an pulse audio indicating, this volume cannot be adjusted.
11. Output Control
Monopolar: Hand Control, Foot Control;
12. Main Supply: AC220V±10% 50Hz±2%
13. Dimension: 400mm×330mm×160mm
14. Net Weight: 5 kg
15. Operation Condition:
Environment Temperature: +5°C~+40°C
Relative Humidity: ≤85%
16. Transport and Storage Condition:
Environment Temperature: -40°C~+50°C
Relative Humidity: ≤90%
Surgical Modes | LP-1D | LP-1E |
Pure Cutting | 350W(500Ω) | 350W(500Ω) |
Blend 1 | 250W(500Ω) | 350W(500Ω) |
Blend 2 | 200W(500Ω) | 350W(500Ω) |
Contact Coagulation | 200W(500Ω) | 350W(500Ω) |
Bipolar Standard Coagulation | 70W(150Ω) | ———— |
Specifacation of Smoke Vacuum
Max Flow Volume: 100 L/ min
Ventilate Strength: 10-100 ( air flow: 10 L/ min - 100 L/ min
Working noise: < 60dB
Control Method: Manual/ Foot/ Auto
Down delay time: 0-60s
Particle Remove Rate: 99.999% @ 0.1um
Bad smell removal rate: 97% @ 1 year
LP-1 leep instruments